Abstract:To accurately evaluate the influence of local strength defects in concrete segments on the safety performance of steel-concrete hybrid towers, a finite element model of the wind turbine was established to explore the effect of local strength defects on the hybrid tower bearing capacity. Taking a 5 MW steel-concrete hybrid tower as the research object, local strength defects were simulated by reducing the concrete strength at segment corners in ABAQUS. Based on static pushover analysis, load-displacement curve analysis, stress analysis and plastic damage analysis were carried out for the hybrid tower structure. The results show that segment local strength defects in segments degrade the ductility of load-displacement curves and induce stress concentration at defect positions, which further leads to structural failure. The influence of segment strength defects is most significant in the middle layer of the tower. When the local concrete strength of segments is reduced by 12.5%, 37.5% and 62.5% in turn, the ductility coefficients decrease by 1.2%, 8.4% and 19.0%, respectively. In addition, local strength defects in middle-layer segments alter the damage mode of hybrid towers, and the damage expands obliquely from the defect locations and further aggravates stress concentration. The maximum compressive stress of concrete increases sharply by 46.0%, 46.6% and 56.1%, and the maximum tensile stress rises drastically by 184.6%, 157.2% and 221.0%, all exceeding the code-specified limit values. The research findings reveal the influencing law of local strength defects on damage evolution and failure characteristics of hybrid towers, which can provide theoretical and technical support for safety assessment and optimal design of defective hybrid towers with defects.