管片局部强度缺陷对混塔承载能力的影响分析
CSTR:
作者:
作者单位:

作者简介:

通讯作者:

中图分类号:

基金项目:

湖南省教育厅优秀青年项目(24B0733)


Analysis of the the influence of local strength defects in concrete segments on the bearing capacity of hybrid towers
Author:
Affiliation:

Fund Project:

  • 摘要
  • |
  • 图/表
  • |
  • 访问统计
  • |
  • 参考文献
  • |
  • 相似文献
  • |
  • 引证文献
  • |
  • 资源附件
  • |
  • 文章评论
    摘要:

    为了准确评估预制管片局部强度缺陷对钢-混凝土组合塔筒安全性能的影响,建立风电机组有限元模型探究管片局部强度缺陷对混塔承载性能的作用规律。以5 MW钢-混凝土组合塔筒为研究对象,在ABAQUS数值分析软件中通过降低管片局部混凝土强度模拟局部强度缺陷,基于静力推覆分析理论对混塔结构进行荷载-位移曲线分析、应力分析及塑性损伤分析。结果表明:管片局部强度缺陷会降低荷载-位移曲线的延性性能,在缺陷部位引发应力集中,进而造成结构破坏;管片局部强度缺陷的影响在塔筒中层最为显著,当管片局部的混凝土强度依次折减12.5%、37.5%与62.5%时,延性系数分别降低1.2%、8.4%、19.0%;此外,中层管片的局部强度缺陷会改变混塔损伤模式,损伤从缺陷处斜向扩展,进一步加剧应力集中,混凝土的最大压应力分别剧增46.0%、46.6%、56.1%,最大拉应力分别剧增184.6%、157.2%、221.0%,应力均超规范限值。研究结果揭示了管片局部强度缺陷对混塔损伤发展与破坏特征的影响规律,可为含缺陷混塔的安全性评估及优化设计提供理论与技术支撑。

    Abstract:

    To accurately evaluate the influence of local strength defects in concrete segments on the safety performance of steel-concrete hybrid towers, a finite element model of the wind turbine was established to explore the effect of local strength defects on the hybrid tower bearing capacity. Taking a 5 MW steel-concrete hybrid tower as the research object, local strength defects were simulated by reducing the concrete strength at segment corners in ABAQUS. Based on static pushover analysis, load-displacement curve analysis, stress analysis and plastic damage analysis were carried out for the hybrid tower structure. The results show that segment local strength defects in segments degrade the ductility of load-displacement curves and induce stress concentration at defect positions, which further leads to structural failure. The influence of segment strength defects is most significant in the middle layer of the tower. When the local concrete strength of segments is reduced by 12.5%, 37.5% and 62.5% in turn, the ductility coefficients decrease by 1.2%, 8.4% and 19.0%, respectively. In addition, local strength defects in middle-layer segments alter the damage mode of hybrid towers, and the damage expands obliquely from the defect locations and further aggravates stress concentration. The maximum compressive stress of concrete increases sharply by 46.0%, 46.6% and 56.1%, and the maximum tensile stress rises drastically by 184.6%, 157.2% and 221.0%, all exceeding the code-specified limit values. The research findings reveal the influencing law of local strength defects on damage evolution and failure characteristics of hybrid towers, which can provide theoretical and technical support for safety assessment and optimal design of defective hybrid towers with defects.

    参考文献
    相似文献
    引证文献
引用本文

王真真,刘哲锋,王玉奎.管片局部强度缺陷对混塔承载能力的影响分析[J].河北工业科技,2026,43(5):387-395

复制
分享
相关视频

文章指标
  • 点击次数:
  • 下载次数:
  • HTML阅读次数:
  • 引用次数:
历史
  • 收稿日期:2026-03-10
  • 最后修改日期:2026-08-13
  • 录用日期:
  • 在线发布日期: 2026-10-14
  • 出版日期:
文章二维码