Abstract:To address the difficulty of online detection of liquid accumulation in coalbed methane gathering pipelines, a clamp-on ultrasonic guided wave-based liquid level measurement method for horizontal pipes was proposed. Firstly, the proposed method utilized the energy leakage effect of guided waves induced by liquid loading and established the relationship between liquid level and received signal energy by analyzing the propagation characteristics of guided waves. Secondly, based on the propagation theory and dispersion characteristics of guided waves in cylindrical pipes, an appropriate guided wave mode for liquid level measurement was determined. A clamp-on experimental system was constructed to perform measurements under different liquid level conditions, and a calibration model between liquid level and guided wave signal energy was established. The results show that the guided wave signal energy exhibits a monotonically decreasing nonlinear variation with increasing liquid level. The generalized sigmoid function can effectively describe the relationship between liquid level and signal energy, achieving a fitting coefficient of determination of 0.992. The repeatability standard deviation is 1.61%, and the average relative error of liquid level estimation is 0.27%. The proposed method requires no modification of the pipeline structure and provides a practical non-invasive solution for monitoring liquid accumulation in coalbed methane gathering pipelines.